MIL-L-850E
TABLE IV.
CLASSIFICATION OF DEFECTS.
DEFECTS
CATEGORIES
CRITICAL
Components damaged, incorrect, missing, misfitting
1
or faulty, impairing the function of the preserver
as life saving equipment.
MAJOR
Positioning of harness incorrect.
101
Stitching of cotton drill, webbing, and tapes
102
non-conforming; not correct type stitch.
Slide fastener fly, slider protection patch,
103
chafing patch, and safety tab (as applicable)
not located as specified.
Dimensions not as specified on applicable drawings.
104
MINOR
Completed preserver not clean; evidence of dirt or
201
oil spots.
Improper tensioning in stitching `in parts other
202
than harness.
Incorrect or illegible marking or both of
203
preserver.
1
Test procedures.
4.6
All tests not herein described shall be in
4.6.1
General.
accordance with the methods specified in FED-STD-191; method
5660 shall be used for all light fastness tests.
4.6.2 Operation of post stud fasteners. The waist strap and collar
post stud fasteners shall be opened and closed five times. The
fasteners shall be capable of easy opening and positive closures.